Leave Your Message

Low Frequency Pneumatic Isolation Solutions for Precision Equipment - Top Suppliers and Factory in China

Low frequency vibrations and shocks can significantly impact the accuracy, repeatability, and throughput of precision measuring, positioning, and manufacturing equipment. In today's competitive environment, manufacturing, metrology, engineering, and research facilities in China require enhanced dynamic stability to achieve finer resolution in their finished products. Implementing low frequency and ultra-low frequency vibration isolation solutions is essential for improving the vibration environment, thereby increasing precision manufacturing accuracy and moving towards a vibration-free zone.


Vibrations from machinery and other acoustic sources can be transmitted to support structures, such as facility floors, leading to a detrimental environment with excessive vibration levels. This is a critical concern for suppliers and manufacturers aiming for high-performance outcomes.


Various equipment and processes adversely affected by vibration include precision machine tools, coordinate measuring machines, magnetic resonance imaging (MRI/NMR) systems, laboratory instruments, and semiconductor processing tools. To ensure optimal performance, vibration isolation is crucial to mitigate unwanted vibrations and keep their negative effects within acceptable limits. Isolators are specifically designed to offer vibration and shock protection for these sensitive types of equipment.


As a leading factory in China, we are committed to providing innovative vibration isolation solutions tailored to meet the diverse needs of our clients. By partnering with us, suppliers can enhance their operational efficiency and ensure the longevity of their equipment.

    Precision-Aire™ Leveling Isolators (PAL)

    PAL-type pneumatic isolators provide superior low frequency isolation for metrology instruments, electron microscopes, MRI units, coordinate measuring machines and precision manufacturing equipment.

    PAL isolators react quickly to changes in the supported load and to center of gravity shifts by automatically releveling to a preset position.

    A pneumatic isolation system’s performance is a compromise between natural frequency (isolation), valve leveling accuracy and settling time.

    Settling time can be defined as the time it takes for an isolation system’s motion to return to a predetermined reference with respect to a defined input disturbance. The disturbance can be an environmental input or machine induced, such as a gantry or stage movement.

    Settling time is minimal with optimum damping and corresponding valve flow. Long settling times using pneumatic isolators are unacceptable because precision measuring and positioning machines can suffer repeatability errors and throughput losses.

    Precision-Aire Leveling Isolators (PAL)

    Custom/OEM Isolators

    High-end three-dimensional flexible robotic cutting applications, to achieve bevel cutting function, the pipe and the torch using the servo positioning function.

    Isolators for OEM applications or having custom requirements are available for easy integration into machine designs. For cleanroom applications, the exhaust air from the leveling valves is vented and the isolators are made using cleanroom compatible materials, cleaned and packaged. Isolators can also be made using nonmagnetic materials.

    Custom/OEM Isolators

    Leveling Valves

    A wide range of leveling valves are available. Leveling valves have accuracies from +/- 0.006” (0.15 mm) to +/- 0.001” (0.025 mm)* with adjustable flow rates to accommodate application requirements. Valve stiffness, flow rate and accuracy are important variables to optimum isolator settling time and isolation efficiency.

    Leveling Valve Diagram
    Leveling Valve Unit

    Precision-Aire™ Pneumatic Leveling Mounts (PLM)

    PLM mounts provide low frequency vibration and shock control for surface plates, coordinate measuring machines, fans, air compressors, motor/generator sets, high-speed punch presses and more.

    The Fabreeka PLM series pneumatic isolation mounts are low frequency vibration and shock isolators that provide both attenuation of disturbing vibration and equipment leveling.

    For vibration control applications, the pneumatic (pressurized) portion of these mounts provides significant reduction of vibration amplitudes occurring at frequencies above 5 Hz, having a natural frequency as low as 3 Hz.

    PLM isolation mounts will also continue to isolate with no pressure having a vertical natural frequency of approximately 10 Hz, isolating frequencies above 14 Hz.

    The vertical to horizontal natural frequency ratio is approximately 1:1 with a high degree of horizontal stability.

    For shock or impact applications, the outer elastomeric wall construction provides a high deflection shock mount. A low natural frequency (3 Hz) can be maintained by utilizing an external spacer to prevent a “bottom out” condition.

    Precision-Aire Pneumatic Leveling Mounts
    Frequently Asked Questions (FAQ)

    What are the primary applications for PAL-type pneumatic isolators?

    PAL-type pneumatic isolators are designed to provide superior low frequency isolation for metrology instruments, electron microscopes, MRI units, coordinate measuring machines, and precision manufacturing equipment.

    How do PAL isolators maintain position during load shifts?

    They react rapidly to changes in the supported load and center of gravity shifts by automatically releveling to a preset position using leveling valves.

    Can these pneumatic isolators be customized for cleanrooms?

    Yes. For cleanroom environments, the exhaust air from the leveling valves is vented, and the isolators are constructed from cleanroom-compatible, nonmagnetic materials.

    What is the accuracy range of the leveling valves?

    Leveling valves are available with positioning accuracies ranging from +/- 0.006” (0.15 mm) to +/- 0.001” (0.025 mm), featuring adjustable flow rates to optimize settling times.

    How do PLM mounts perform without air pressure?

    Without pressure, PLM mounts will continue to isolate with a vertical natural frequency of approximately 10 Hz, isolating frequencies above 14 Hz.